# Solar PV Design Calculations API > Design-stage string sizing, DC/AC ratio and clipping, POA irradiance transposition, PVWatts energy yield, row spacing, horizon shading, system loss stack, battery backup sizing, tariff savings, financial payback, module layout fit, NEC 690.8 current, module spec compare, and PAN/OND parsing from caller inputs only. Each paid operation uses a fixed USDC price on Base with the x402 exact scheme. Unpaid GET, HEAD, and POST return 402 payment terms (POST validates the body only after payment terms are satisfied). A request that carries payment-signature is not yet charged: settlement happens only after a successful (2xx) result. HTTP 4xx/5xx are not charged. Coverage bodies with status complete, partial, or failed all return HTTP 200 and are charged at the full listed price. Settled 2xx responses include a payment-response header; 4xx/5xx do not. Follow https://www.brainiac.software/agent-instructions.txt for install, payment pins, idempotency, and billing rules. - Product: https://www.brainiac.software/api/solar-design - Docs: https://www.brainiac.software/api/solar-design/docs - OpenAPI: https://www.brainiac.software/api/solar-design/openapi.json - Contact: support@brainiac.software (https://www.brainiac.software/contact) ## Operations ### POST /api/v1/solar-design/string-sizing $0.03 USDC. Compute minimum and maximum modules per series string and maximum parallel strings per MPPT from module temperature coefficients, site temperatures and inverter DC limits. Inputs: module, site, inverter Docs: https://www.brainiac.software/api/solar-design/docs#solar-design-string-sizing Example request: ```json { "module": { "voc": 49.9, "vmp": 41.96, "isc": 14, "imp": 13.11, "tempCoeffVoc": -0.128, "tempCoeffVocUnit": "V_per_C", "tempCoeffVmp": -0.003, "tempCoeffVmpUnit": "fraction_per_C", "tempCoeffIsc": 0.00728, "tempCoeffIscUnit": "A_per_C", "bifacialGain": 0 }, "site": { "recordLowAmbient": -10, "maxCellTemp": 70 }, "inverter": { "maxDcVoltage": 1500, "mpptMin": 500, "mpptMax": 1300, "maxInputCurrentPerMppt": 30, "maxIscPerMppt": null } } ``` Example response: ```json { "vocAtTmin": 54.379999999999995, "vmpAtTmax": 36.2954, "vmpAtTmin": 46.3658, "iscAtTmax": 14.3276, "maxModulesBySystemVoltage": 27, "minModulesByMppt": 14, "maxModulesByMpptUpper": 28, "recommendedRange": [ 14, 27 ], "maxStringsPerMppt": 2, "feasible": true, "sources": [ { "source": "Caller-supplied module, inverter, irradiance and site inputs processed locally", "url": "https://www.brainiac.software/api/v1/solar-design", "retrievedAt": "2026-11-14", "status": "ok" }, { "source": "pvlib python SPA / irradiance algorithms (BSD-3-Clause); NREL SPA Reda & Andreas 2004/2008; Perez et al. 1990", "url": "https://github.com/pvlib/pvlib-python", "retrievedAt": "2026-11-14", "status": "ok" } ], "limitations": [ "Outputs are design-stage calculations on caller-supplied inputs for human review. They are not engineering stamps, code…", "recordLowAmbient is used as the cell temperature for Voc (night-to-dawn assumption).", "…" ] } ``` ### POST /api/v1/solar-design/dc-ac-ratio-check $0.03 USDC. Compute the DC/AC ratio and optionally estimate AC energy and clipping from a caller DC power series with constant efficiency or a PVWatts inverter curve. Inputs: dcNameplateKw, acRatingKw, inverterEfficiency?, dcPowerSeriesKw?, intervalHours?, ratioWarnAbove?, useCecCurve? Docs: https://www.brainiac.software/api/solar-design/docs#solar-design-dc-ac-ratio-check Example request: ```json { "dcNameplateKw": 29.7, "acRatingKw": 25, "inverterEfficiency": 0.96, "dcPowerSeriesKw": [ 0, 2, 8, 15, 22, 27, 29, 27, 22, 15, 8, 2, 0 ], "intervalHours": 1, "ratioWarnAbove": 1.3 } ``` Example response: ```json { "dcAcRatio": 1.188, "warnings": [], "acEnergyKwh": 165.24, "clippedEnergyKwh": 4.679999999999996, "clippingFraction": 0.02754237288135591, "sources": [ { "source": "Caller-supplied module, inverter, irradiance and site inputs processed locally", "url": "https://www.brainiac.software/api/v1/solar-design", "retrievedAt": "2026-11-14", "status": "ok" }, { "source": "PVWatts Version 5 Manual (Dobos 2014, NREL/TP-6A20-62641)", "url": "https://www.nrel.gov/docs/fy14osti/62641.pdf", "retrievedAt": "2026-11-14", "status": "ok" } ], "limitations": [ "Outputs are design-stage calculations on caller-supplied inputs for human review. They are not engineering stamps, code…", "Without dcPowerSeriesKw only the nameplate DC/AC ratio is returned.", "…" ] } ``` ### POST /api/v1/solar-design/poa-irradiance-transpose $0.04 USDC. Compute plane-of-array irradiance with isotropic, Hay-Davies or Perez sky models and NREL SPA solar geometry from caller irradiance records. Inputs: latitude, longitude, elevation?, tilt, azimuth, albedo?, model?, records, pressurePa?, temperatureC?, deltaT? Docs: https://www.brainiac.software/api/solar-design/docs#solar-design-poa-irradiance-transpose Example request: ```json { "latitude": 51.5, "longitude": -0.13, "elevation": 0, "tilt": 30, "azimuth": 180, "albedo": 0.2, "model": "perez", "records": [ { "time": "2026-06-21T12:00:00Z", "ghi": 800, "dni": 600, "dhi": 250 } ] } ``` Example response: ```json { "records": [ { "time": "2026-06-21T12:00:00Z", "apparentZenith": 28.05788760207966, "solarAzimuth": 178.86045677515926, "aoi": 2.0192198013423734, "dniExtra": 1321.6235925714136, "poaGlobal": 894.160192475058, "poaDirect": 599.6274382774938, "poaSkyDiffuse": 283.8147865003193, "poaGroundDiffuse": 10.717967697244903 } ], "sources": [ { "source": "Caller-supplied module, inverter, irradiance and site inputs processed locally", "url": "https://www.brainiac.software/api/v1/solar-design", "retrievedAt": "2026-11-14", "status": "ok" }, { "source": "pvlib python SPA / irradiance algorithms (BSD-3-Clause); NREL SPA Reda & Andreas 2004/2008; Perez et al. 1990", "url": "https://github.com/pvlib/pvlib-python", "retrievedAt": "2026-11-14", "status": "ok" } ], "limitations": [ "Outputs are design-stage calculations on caller-supplied inputs for human review. They are not engineering stamps, code…", "Solar position uses NREL SPA as in pvlib method=nrel_numpy with bundled coefficient tables.", "…" ] } ``` ### POST /api/v1/solar-design/energy-yield-estimate $0.04 USDC. Estimate AC energy from caller POA irradiance and temperatures using the PVWatts v5 DC and inverter models with a transparent loss stack. Inputs: dcNameplateW, gammaPdc, acRatingW, inverterNominalEfficiency?, lossesPercent?, temperatureModel?, records?, monthly?, intervalHours? Docs: https://www.brainiac.software/api/solar-design/docs#solar-design-energy-yield-estimate Example request: ```json { "dcNameplateW": 29700, "gammaPdc": -0.0034, "acRatingW": 25000, "inverterNominalEfficiency": 0.96, "lossesPercent": 14.08, "temperatureModel": { "type": "pvsyst", "uc": 29, "uv": 0, "alphaAbsorption": 0.9, "moduleEfficiency": 0.1 }, "records": [ { "time": "2026-06-21T12:00:00Z", "poa": 800, "ambientTemp": 20, "windSpeed": 1 } ], "intervalHours": 1 } ``` Example response: ```json { "records": [ { "time": "2026-06-21T12:00:00Z", "cellTemp": 42.3448275862069, "pdc": 22358.815448275862, "pdcAfterLosses": 19210.69423315862, "pac": 18483.439181716883 } ], "totalAcKwh": 18.483439181716882, "lossStack": { "totalPercent": 14.08 }, "accuracyNote": "interval_mode", "sources": [ { "source": "Caller-supplied module, inverter, irradiance and site inputs processed locally", "url": "https://www.brainiac.software/api/v1/solar-design", "retrievedAt": "2026-11-14", "status": "ok" }, { "source": "PVWatts Version 5 Manual (Dobos 2014, NREL/TP-6A20-62641)", "url": "https://www.nrel.gov/docs/fy14osti/62641.pdf", "retrievedAt": "2026-11-14", "status": "ok" }, "…" ], "limitations": [ "Outputs are design-stage calculations on caller-supplied inputs for human review. They are not engineering stamps, code…", "PVWatts v5 DC and inverter models; cell temperature uses the PVsyst model when cellTemp is omitted.", "…" ] } ``` ### POST /api/v1/solar-design/row-spacing $0.02 USDC. Compute row height, shadow gap, row pitch and ground coverage ratio that avoid row-to-row shading at a design sun position. Inputs: moduleSlopeLength, tilt, arrayAzimuth?, sun?, designTimes?, latitude?, longitude?, elevation?, groundSlope? Docs: https://www.brainiac.software/api/solar-design/docs#solar-design-row-spacing Example request: ```json { "moduleSlopeLength": 2.278, "tilt": 30, "arrayAzimuth": 180, "sun": { "elevation": 20, "azimuth": 140 }, "groundSlope": 0 } ``` Example response: ```json { "rowHeight": 1.1389999999999998, "shadowGap": 2.3972416933258462, "rowPitch": 4.370047563146798, "gcr": 0.5212757909572157, "sunElevation": 20, "sunAzimuth": 140, "sources": [ { "source": "Caller-supplied module, inverter, irradiance and site inputs processed locally", "url": "https://www.brainiac.software/api/v1/solar-design", "retrievedAt": "2026-11-14", "status": "ok" }, { "source": "pvlib python SPA / irradiance algorithms (BSD-3-Clause); NREL SPA Reda & Andreas 2004/2008; Perez et al. 1990", "url": "https://github.com/pvlib/pvlib-python", "retrievedAt": "2026-11-14", "status": "ok" } ], "limitations": [ "Outputs are design-stage calculations on caller-supplied inputs for human review. They are not engineering stamps, code…", "Spacing avoids row-to-row shading at the design sun position only; seasonal extremes should be checked separately." ] } ``` ### POST /api/v1/solar-design/horizon-shading-loss $0.03 USDC. Estimate beam and isotropic sky-diffuse losses caused by a caller far-field horizon profile against sun positions and beam POA. Inputs: horizon, records?, latitude?, longitude?, elevation?, times?, beamPoa? Docs: https://www.brainiac.software/api/solar-design/docs#solar-design-horizon-shading-loss Example request: ```json { "horizon": [ { "azimuth": 0, "elevation": 10 }, { "azimuth": 90, "elevation": 10 }, { "azimuth": 180, "elevation": 10 }, { "azimuth": 270, "elevation": 10 } ], "records": [ { "sunElevation": 25, "sunAzimuth": 160, "beamPoa": 500 } ] } ``` Example response: ```json { "beamLossFraction": 0, "skyDiffuseLossFraction": 0.03015368960704569, "blockedHours": 0, "sources": [ { "source": "Caller-supplied module, inverter, irradiance and site inputs processed locally", "url": "https://www.brainiac.software/api/v1/solar-design", "retrievedAt": "2026-11-14", "status": "ok" }, { "source": "pvlib python SPA / irradiance algorithms (BSD-3-Clause); NREL SPA Reda & Andreas 2004/2008; Perez et al. 1990", "url": "https://github.com/pvlib/pvlib-python", "retrievedAt": "2026-11-14", "status": "ok" } ], "limitations": [ "Outputs are design-stage calculations on caller-supplied inputs for human review. They are not engineering stamps, code…", "Far-field horizon only; near-field objects closer than the array scale are not modelled.", "…" ] } ``` ### POST /api/v1/solar-design/system-loss-stack $0.01 USDC. Combine individual loss percentages into a total system loss using PVWatts multiplicative derating, with optional defaults for missing categories. Inputs: losses?, useDefaultsForMissing? Docs: https://www.brainiac.software/api/solar-design/docs#solar-design-system-loss-stack Example request: ```json { "losses": { "soiling": 2, "shading": 3, "snow": 0, "mismatch": 2, "wiring": 2, "connections": 0.5, "lid": 1.5, "nameplate": 1, "age": 0, "availability": 3 }, "useDefaultsForMissing": true } ``` Example response: ```json { "totalPercent": 14.075660688264469, "derate": 0.8592433931173553, "items": [ { "name": "soiling", "percent": 2, "source": "caller" }, { "name": "shading", "percent": 3, "source": "caller" }, "…" ], "sources": [ { "source": "Caller-supplied module, inverter, irradiance and site inputs processed locally", "url": "https://www.brainiac.software/api/v1/solar-design", "retrievedAt": "2026-11-14", "status": "ok" }, { "source": "PVWatts Version 5 Manual (Dobos 2014, NREL/TP-6A20-62641)", "url": "https://www.nrel.gov/docs/fy14osti/62641.pdf", "retrievedAt": "2026-11-14", "status": "ok" } ], "limitations": [ "Outputs are design-stage calculations on caller-supplied inputs for human review. They are not engineering stamps, code…", "Losses combine multiplicatively per PVWatts v5: total = 100·[1 − Π(1 − l_i/100)]." ] } ``` ### POST /api/v1/solar-design/battery-backup-sizing $0.03 USDC. Size battery energy and inverter continuous/surge power needed to back up critical loads for a target autonomy with DoD and efficiency derates. Inputs: loads, autonomyHours, depthOfDischarge, dischargeEfficiency, temperatureDerate?, inverterMargin?, pvRechargeKwhPerDay?, simultaneousStart? Docs: https://www.brainiac.software/api/solar-design/docs#solar-design-battery-backup-sizing Example request: ```json { "loads": [ { "name": "fridge+lights+router", "powerKw": 2, "hoursPerDay": 24, "surgeKw": 6 } ], "autonomyHours": 10, "depthOfDischarge": 0.9, "dischargeEfficiency": 0.95, "temperatureDerate": 1, "inverterMargin": 1.25, "pvRechargeKwhPerDay": 0 } ``` Example response: ```json { "energyNeededKwh": 20, "nominalCapacityKwh": 23.391812865497077, "inverterContinuousKw": 2.5, "inverterSurgeKw": 6, "sources": [ { "source": "Caller-supplied module, inverter, irradiance and site inputs processed locally", "url": "https://www.brainiac.software/api/v1/solar-design", "retrievedAt": "2026-11-14", "status": "ok" } ], "limitations": [ "Outputs are design-stage calculations on caller-supplied inputs for human review. They are not engineering stamps, code…", "temperatureDerate is a caller datasheet value; no battery thermal model is applied.", "…" ] } ``` ### POST /api/v1/solar-design/tariff-savings $0.03 USDC. Compute bill savings from caller interval generation and load under a time-of-use tariff with export credit, net metering or no export value. Inputs: intervalHours?, loadKwh, generationKwh, importPrice, exportMode?, exportPrice?, fixedCharges?, demandCharge?, billingPeriods? Docs: https://www.brainiac.software/api/solar-design/docs#solar-design-tariff-savings Example request: ```json { "intervalHours": 1, "loadKwh": [ 0.5, 0.5, 0.5, 0.5, 0.5, 0.5, 0.5, 1.5, 1, 0.8, 0.8, 0.8, 0.9, 0.9, 0.8, 0.8, 1, 2, 2.5, 2, 1.5, 1, 0.7, 0.5 ], "generationKwh": [ 0, 0, 0, 0, 0, 0, 0.2, 0.8, 1.5, 2.2, 2.8, 3, 3.1, 2.9, 2.4, 1.7, 0.9, 0.3, 0, 0, 0, 0, 0, 0 ], "importPrice": [ 0.1, 0.1, 0.1, 0.1, 0.1, 0.1, 0.1, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.4, 0.4, 0.4, 0.4, 0.25, 0.1, 0.1, 0.1 ], "exportMode": "export_rate", "exportPrice": 0.05, "fixedCharges": 0, "demandCharge": null } ``` Example response: ```json { "billWithoutPv": 6.02, "billWithPv": 2.9799999999999995, "savings": 3.04, "importKwh": 14, "exportKwh": 12.8, "selfConsumedKwh": 9, "selfConsumptionRate": 0.4128440366972478, "sources": [ { "source": "Caller-supplied module, inverter, irradiance and site inputs processed locally", "url": "https://www.brainiac.software/api/v1/solar-design", "retrievedAt": "2026-11-14", "status": "ok" } ], "limitations": [ "Outputs are design-stage calculations on caller-supplied inputs for human review. They are not engineering stamps, code…", "Tariff prices and export rules are caller-supplied; no utility rate database is queried.", "…" ] } ``` ### POST /api/v1/solar-design/financial-payback $0.03 USDC. Compute simple payback, NPV, IRR and LCOE from capex, incentives, year-1 energy, degradation, O&M and price escalation. Inputs: capex, upfrontIncentives?, year1EnergyKwh, degradation?, energyValuePerKwh, energyEscalation?, omPerYear?, omEscalation?, years, discountRate Docs: https://www.brainiac.software/api/solar-design/docs#solar-design-financial-payback Example request: ```json { "capex": 20000, "upfrontIncentives": 3000, "year1EnergyKwh": 9000, "degradation": 0.005, "energyValuePerKwh": 0.25, "energyEscalation": 0.02, "omPerYear": 200, "omEscalation": 0.02, "years": 25, "discountRate": 0.05 } ``` Example response: ```json { "netCapex": 17000, "year1CashFlow": 2050, "npv": 16267.394915881545, "irr": 0.12612992523272165, "paybackYears": 7.889390667220237, "lcoe": 0.1688917763747619, "sources": [ { "source": "Caller-supplied module, inverter, irradiance and site inputs processed locally", "url": "https://www.brainiac.software/api/v1/solar-design", "retrievedAt": "2026-11-14", "status": "ok" } ], "limitations": [ "Outputs are design-stage calculations on caller-supplied inputs for human review. They are not engineering stamps, code…", "Incentives are caller numbers; no tax-credit rules are encoded.", "…" ] } ``` ### POST /api/v1/solar-design/module-layout-fit $0.04 USDC. Maximise the number of modules on a roof-face polygon with caller setbacks, orientation, gaps and obstruction polygons. Inputs: roof, setback, module, gap?, orientations?, obstructions?, gridOffsets? Docs: https://www.brainiac.software/api/solar-design/docs#solar-design-module-layout-fit Example request: ```json { "roof": [ [ 0, 0 ], [ 10, 0 ], [ 10, 6 ], [ 0, 6 ] ], "setback": 0.5, "module": { "width": 1.134, "height": 2.278 }, "gap": 0.02, "orientations": [ "portrait", "landscape" ], "obstructions": [], "gridOffsets": 10 } ``` Example response: ```json { "best": { "orientation": "portrait", "count": 14, "rows": 2, "columns": 7 }, "candidates": [ { "orientation": "portrait", "count": 14 }, { "orientation": "landscape", "count": 12 } ], "placements": [ { "x": 0.5, "y": 0.5, "w": 1.134, "h": 2.278 }, { "x": 1.654, "y": 0.5, "w": 1.134, "h": 2.278 }, "…" ], "sources": [ { "source": "Caller-supplied module, inverter, irradiance and site inputs processed locally", "url": "https://www.brainiac.software/api/v1/solar-design", "retrievedAt": "2026-11-14", "status": "ok" } ], "limitations": [ "Outputs are design-stage calculations on caller-supplied inputs for human review. They are not engineering stamps, code…", "Roof polygon is treated in the roof plane (2D metres). Setbacks are caller-supplied; jurisdiction rules vary.", "…" ] } ``` ### POST /api/v1/solar-design/nec-690-current $0.02 USDC. Compute PV circuit maximum current and minimum conductor ampacity using NEC 690.8 125% factors for the selected code edition. Inputs: edition?, moduleIsc, parallelStrings?, continuousFactor? Docs: https://www.brainiac.software/api/solar-design/docs#solar-design-nec-690-current Example request: ```json { "edition": "2023", "moduleIsc": 14, "parallelStrings": 2, "continuousFactor": 1.25 } ``` Example response: ```json { "maxCircuitCurrent": 35, "minConductorAmpacity": 43.75, "minOcpdRating": 43.75, "perStringMaxCurrent": 17.5, "edition": "2023", "sources": [ { "source": "Caller-supplied module, inverter, irradiance and site inputs processed locally", "url": "https://www.brainiac.software/api/v1/solar-design", "retrievedAt": "2026-11-14", "status": "ok" }, { "source": "NFPA 70 National Electrical Code §690.8 factors (2017/2020/2023 editions); formula cited only, NFPA text not vendored", "url": "https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70", "retrievedAt": "2026-11-14", "status": "ok" } ], "limitations": [ "Outputs are design-stage calculations on caller-supplied inputs for human review. They are not engineering stamps, code…", "Applies NEC 690.8(A)(1)(a)(1) and 690.8(B) 125% factors only; 2023 alternative methods are out of scope.", "…" ] } ``` ### POST /api/v1/solar-design/module-spec-compare $0.02 USDC. Normalise and compare module datasheet values for efficiency, W/m², temperature-adjusted power, price per watt and warranty retention. Inputs: modules, referenceCellTemp? Docs: https://www.brainiac.software/api/solar-design/docs#solar-design-module-spec-compare Example request: ```json { "modules": [ { "name": "A", "pmax": 550, "width": 1.134, "height": 2.278, "tempCoeffPmax": -0.34, "price": 165, "warrantyYear25Retention": 0.874 }, { "name": "B", "pmax": 430, "width": 1.134, "height": 1.762, "tempCoeffPmax": -0.29, "price": 140, "warrantyYear25Retention": 0.889 } ], "referenceCellTemp": 45 } ``` Example response: ```json { "modules": [ { "name": "A", "efficiency": 0.2129099290351851, "wattsPerM2": 212.90992903518512, "pricePerW": 0.3, "pmaxAtRefTemp": 512.6, "warrantyYear25Retention": 0.874, "noct": null, "pmaxNoct": null }, { "name": "B", "efficiency": 0.21520358258912933, "wattsPerM2": 215.20358258912933, "pricePerW": 0.32558139534883723, "pmaxAtRefTemp": 405.06, "warrantyYear25Retention": 0.889, "noct": null, "pmaxNoct": null } ], "ranking": { "efficiency": [ "B", "A" ], "wattsPerM2": [ "B", "A" ], "pricePerW": [ "A", "B" ], "pmaxAtRefTemp": [ "A", "B" ], "warrantyYear25Retention": [ "B", "A" ] }, "sources": [ { "source": "Caller-supplied module, inverter, irradiance and site inputs processed locally", "url": "https://www.brainiac.software/api/v1/solar-design", "retrievedAt": "2026-11-14", "status": "ok" } ], "limitations": [ "Outputs are design-stage calculations on caller-supplied inputs for human review. They are not engineering stamps, code…", "Efficiency = pmax/(1000·area) at STC. Optional NOCT values are reported separately and never mixed with STC.", "…" ] } ``` ### POST /api/v1/solar-design/pan-ond-parse $0.02 USDC. Parse PVsyst PAN (module) and OND (inverter) text files into nested raw JSON and a normalised datasheet object. Inputs: fileType, content Docs: https://www.brainiac.software/api/solar-design/docs#solar-design-pan-ond-parse Example request: ```json { "fileType": "pan", "content": "PVObject_=pvModule\n Version=7.2\n PVObject_Commercial=pvCommercial\n Manufacturer=ET SOLAR\n Model=ET-M772BH550GL\n Width=1.134\n Height=2.278\n PNom=550.0\n Isc=14.0\n Voc=49.9\n Imp=13.11\n Vmp=41.96\n muISC=7.28\n muVocSpec=-128.0\n NCelS=72\n BifacialityFactor=0.7\n" } ``` Example response: ```json { "raw": { "PVObject_": { "PVObject_": "pvModule", "Version": 7.2, "Flags": "$00900243", "PVObject_Commercial": { "PVObject_Commercial": "pvCommercial", "Comment": "ET SOLAR", "Flags": "$0041", "Manufacturer": "ET SOLAR", "Model": "ET-M772BH550GL", "DataSource": "Manufacturer 2021", "YearBeg": 2021, "Width": 1.134, "Height": 2.278, "Depth": 0.035, "Weight": 32, "NPieces": 100, "PriceDate": "06/04/22 12:39" }, "Technol": "mtSiMono", "NCelS": 72, "NCelP": 2, "NDiode": 3, "SubModuleLayout": "slTwinHalfCells", "FrontSurface": "fsARCoating", "GRef": 1000, "TRef": 25, "PNom": 550, "PNomTolUp": 0.9, "BifacialityFactor": 0.7, "Isc": 14, "Voc": 49.9, "Imp": 13.11, "Vmp": 41.96, "muISC": 7.28, "muVocSpec": -128, "muPmpReq": -0.34, "RShunt": 300, "Rp_0": 2000, "Rp_Exp": 5.5, "RSerie": 0.203, "Gamma": 0.98, "muGamma": -0.0001, "VMaxIEC": 1500, "VMaxUL": 1500, "Absorb": 0.9, "ARev": 3.2, "BRev": 16.716, "RDiode": 0.01, "VRevDiode": -0.7, "IMaxDiode": 30, "AirMassRef": 1.5, "CellArea": 165.1, "SandiaAMCorr": 50, "PVObject_IAM": { "PVObject_IAM": "pvIAM", "Flags": "$00", "IAMMode": "UserProfile", "IAMProfile": { "IAMProfile": "TCubicProfile", "NPtsMax": 9, "NPtsEff": 9, "LastCompile": "$B18D", "Mode": 3, "Point_1": [ 0, 1 ], "Point_2": [ 20, 1 ], "Point_3": [ 30, 1 ], "Point_4": [ 40, 0.99 ], "Point_5": [ 50, 0.98 ], "Point_6": [ 60, 0.96 ], "Point_7": [ 70, 0.89 ], "Point_8": [ 80, 0.66 ], "Point_9": [ 90, 0 ] } } } }, "normalized": { "manufacturer": "ET SOLAR", "model": "ET-M772BH550GL", "pNom": 550, "voc": 49.9, "isc": 14, "vmp": 41.96, "imp": 13.11, "muIscAPerC": 0.00728, "muVocVPerC": -0.128, "cellsSeries": 72, "width": 1.134, "height": 2.278, "bifacialityFactor": 0.7, "iamProfile": [ [ 0, 1 ], [ 20, 1 ], "…" ] }, "sources": [ { "source": "PVsyst PAN/OND text format parsed locally (pvlib iotools.read_panond behaviour)", "url": "https://github.com/pvlib/pvlib-python", "retrievedAt": "2026-11-14", "status": "ok" } ], "limitations": [ "Outputs are design-stage calculations on caller-supplied inputs for human review. They are not engineering stamps, code…", "Binary/legacy (pre-6.x) files are rejected as unsupported_format.", "…" ] } ```